Dell 7.4 manual Disk medium error on virtual disk has been corrected

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 180
Image 180

Related Alert Information

SNMP Trap Numbers

NOTE: If the unrecoverable medium error has not been corrected, it may be reported again by the system. This error can be fixed by writing data on the affected area or deleting and recreating the Virtual Disk as demonstrated in the following procedure.

1.Back up the data.

2.Delete the Virtual Disk.

3.Recreate the Virtual Disk using the same parameters like size, RAID level, disks, etc.

4.Restore data.

Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: None

1204

Event ID — 2418

Description

Disk medium error on virtual disk has been corrected

Severity

Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2425

Description

State change on Physical disk from READY to Non-RAID.

Severity

Informational

Cause and

Cause: User triggered action.

Action

Action: Configure the drive to be non-raid using CLI/GUI.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

901

Numbers

 