Event Message

Severity

Cause

 

 

 

PS 1 Status: Power supply

Warning/Critical

This event is generated when an

sensor for PS 1,

 

invalid power supply

configuration error was

 

configuration is detected.

asserted.

 

 

PS 1 Status: Power supply

Information

This event is generated when the

sensor for PS 1,

 

power supply has recovered

configuration error was

 

from an earlier invalid

deasserted.

 

configuration.

Power supply <number> is

Information

This event is generated when the

present.

 

power supply is plugged in.

Power supply <number> is

Critical

This event is generated when the

absent.

 

power supply is removed.

Power supply <number>

Critical

This event is generated when the

failed.

 

power supply has failed.

A predictive failure

Warning

This event is generated when the

detected on power supply

 

power supply is about to fail.

<number>.

 

 

The power input for power

Critical

This event is generated when

supply <number> is lost.

 

input power is removed from the

 

 

power supply.

 

 

 

The input power for power

Information

This event is generated if the

supply <number> has been

 

power supply has been

restored.

 

reconnected or replaced.

Power supply <number> is

Critical/Warning

This event is generated when an

incorrectly configured.

 

invalid power supply

 

 

configuration is detected.

 

 

 

Power supply <number> is

Information

This event is generated when the

correctly configured.

 

power supply has recovered

 

 

from an earlier invalid

 

 

configuration.

 

 

 

Power supply <number> is

Information

This event is generated when the

operating normally.

 

power supply has recovered

 

 

from an earlier failure event.

 

 

 

Cannot communicate with

Critical

The power supply may operate,

power supply <number>.

 

however power supply

 

 

monitoring is degraded.

 

 

 

The temperature for power

Warning

Temperature of specified power

supply <number> is in a

 

supply entered into non-critical

warning range.

 

state.

209