SNMP Trap

751

Numbers

 

Event ID — 2316

Description

Diagnostic message %1

Severity

Critical / Failure / Error

Cause and

Cause: A diagnostics test failed. The %1 indicates a substitution variable. The text

Action

for this substitution variable is generated by the utility that ran the diagnostics and

 

is displayed with the alert in the alert log. This text can vary depending on the

 

situation.

 

Action: See the documentation for the utility that ran the diagnostics for more

 

information

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2061

SNMP Trap

754

Numbers

 

Event ID — 2318

Description

Problems with the battery or the battery charger have been detected. The battery

 

health is poor.

Severity

Cause and Action

Related Alert Information

SNMP Trap Numbers

Warning / Non-critical

Cause: The battery or the battery charger is not functioning properly.

Action: Replace the battery pack.

Clear Alert Number: None

Related Alert Number: 2188

Local Response Agent (LRA) Number: 2100

1153

Event ID — 2319

Description

Single-bit ECC error. The DIMM is degrading.

Severity

Warning / Non-critical

Cause and

Cause: The DIMM is beginning to malfunction.

Action

Action: Replace the DIMM to avoid data loss or data corruption. The DIMM is a part

 

of the controller battery pack. See your hardware documentation for information

 

on replacing the DIMM or contact technical support.

147

Page 147
Image 147
Dell 7.4 manual Health is poor