Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2176 | |
Description | The controller battery Learn cycle has started. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: 2177 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2177 | |
Description | The controller battery Learn cycle has completed. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: Alert 2177 is a clear alert for alert 2176. |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2178 | |
Description | The controller battery Learn cycle has timed out. |
Severity | Warning / |
Cause and | Cause: The controller battery must be fully charged before the Learn cycle can |
Action | begin. The battery may be unable to maintain a full charge causing the Learn cycle |
| to timeout. Additionally, the battery must be able to maintain cached data for a |
| specified period of time in the event of a power loss. For example, some batteries |
| maintain cached data for 24 hours. If the battery is unable to maintain cached data |
| for the required period of time, then the Learn cycle timeout occurs. |
| Action: Replace the battery pack as the battery is unable to maintain a full charge. |
100