SNMP Trap

754

Numbers

 

Event ID — 2402

Description

Severity

Cause and Action

Related Alert Information

Changing the Physical Disk Power status from 1% to 2% failed.

Failure / Error

Cause: When changing the Physical Disk Power status fails.

Action: Replace the physical disk.

Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: None

SNMP Trap

904

Numbers

 

Event ID — 2403

Description

Virtual Disk is available.

Severity

OK / Normal / Informational

Cause and

Cause: The operating system detects the newly created virtual disk.

Action

Action: None.

 

NOTE: This alert also appears when a CacheCade is created but is not

 

available for the operating system (as it is a CacheCade and not a Virtual Disk).

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2404

Description

Severity

Cause and Action

Related Alert Information

Virtual Disk is not available.

OK / Normal / Informational

Cause: The operating system does not detect the newly created virtual disk.

Action: Wait for some time.

Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: None