Table 3. Alert Message Format

Alert ID

Message Text Displayed in the Storage

Message Text Displayed in the Alert Log

 

Management Service Documentation

with Variable Information Supplied

 

 

 

2127

Background Initialization started

Background Initialization started: Virtual Disk

 

 

3 (Virtual Disk 3) Controller 1 (PERC 5/E

 

 

Adapter)

 

 

 

2334

Controller event log %

Controller event log: Current capacity of the

 

 

battery is above threshold : Controller 1

 

 

(PERC 5/E Adapter)

 

 

 

The variables required to complete the message vary depending on the type of storage object and whether the storage object is in a SCSI or SAS configuration. The following table identifies the possible variables used to identify each storage object.

NOTE: Some alert messages relating to an enclosure or an enclosure component, such as a fan or EMM, are generated by the controller when the enclosure or enclosure component ID cannot be determined.

NOTE: A, B, C and X, Y, Z in the following examples are variables representing the storage object name or number.

Table 4. Message Format with Variables for Each Storage Object

Storage Object

Message Variables

 

 

Controller

Message Format: Controller A (Name)

 

Message Format: Controller A

 

For example, 2326 A foreign configuration has been detected: Controller 1

 

(PERC 5/E Adapter)

 

NOTE: The controller name is not always displayed.

Battery

Message Format: Battery X Controller A

 

For example, 2174 The controller battery has been removed: Battery 0

 

Controller 1

SCSI Physical Disk

Message Format: Physical Disk X:Y Controller A, Connector B

 

For example, 2049 Physical disk removed: Physical Disk 0:14 Controller 1,

 

Connector 0

SAS Physical Disk

Message Format: Physical Disk X:Y:Z Controller A, Connector B

 

For example, 2049 Physical disk removed: Physical Disk 0:0:14 Controller 1,

 

Connector 0

Virtual Disk

Enclosure

SCSI Power Supply

56

Message Format: Virtual Disk X (Name) Controller A (Name)

Message Format: Virtual Disk X Controller A

For example, 2057 Virtual disk degraded: Virtual Disk 11 (Virtual Disk 11) Controller 1 (PERC 5/E Adapter)

NOTE: The virtual disk and controller names are not always displayed.

Message Format: Enclosure X:Y Controller A, Connector B

For example, 2112 Enclosure shutdown: Enclosure 0:2 Controller 1, Connector 0

Message Format: Power Supply X Controller A, Connector B, Target ID C

Page 56
Image 56