Dell 7.4 manual Hot spare Smart polling failed

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 135
Image 135

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2127

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2282

Description

Hot spare SMART polling failed.

Severity

Critical / Failure / Error

Cause and

Cause: The controller firmware attempted a SMART polling on the hot spare but

Action

was unable to complete it. The controller has lost communication with the hot

 

spare.

 

Action: Check the health of the disk assigned as a hot spare. You may need to

 

replace the disk and reassign the hot spare. Make sure the cables are attached

 

securely. See the Server Administrator Storage Management User’s Guide, for more

 

information on checking the cables.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2071

SNMP Trap

904

Numbers

 

Event ID — 2283

Description

A redundant path is broken.

Severity

Warning / Non-critical

Cause and

Cause: The controller has two connectors that are connected to the same

Action

enclosure. The communication path on one connector has lost connection with

 

the enclosure. The communication path on the other connector is reporting this

 

loss.

 

Action: Make sure the cables are attached securely and both enclosure

 

management modules (EMMs) are healthy. See the Cables Attached Correctly

 

section for more information on checking the cables.

Related Alert

Clear Alert Number: 2284

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

135

Page 135
Image 135
Dell 7.4 manual Hot spare Smart polling failed