Event Message | Severity | Cause |
|
|
|
|
| was received from Host) and the |
|
| action is set to power off. |
|
|
|
The OS watchdog timer | Critical | This event is generated when the |
expired. |
| BMC watchdog timer expires and |
|
| no action is set. |
|
|
|
Memory Events
The memory modules can be configured in different ways in particular systems. These messages monitor the status, warning, and configuration information about the memory modules in the system.
Table 12. Memory Events
Event Message | Severity | Cause |
|
|
|
Memory RAID redundancy | Warning | This event is generated when |
degraded. |
| there is a memory failure in a |
|
| |
|
| configuration. |
|
|
|
Memory RAID redundancy | Critical | This event is generated when |
lost. |
| redundancy is lost in a RAID- |
|
| configured memory |
|
| configuration. |
|
|
|
Memory RAID redundancy | Information | This event is generated when the |
regained. |
| redundancy lost or degraded |
|
| earlier is regained in a RAID- |
|
| configured memory |
|
| configuration. |
|
|
|
Memory Mirrored | Warning | This event is generated when |
redundancy degraded. |
| there is a memory failure in a |
|
| mirrored memory configuration. |
|
|
|
Memory Mirrored | Critical | This event is generated when |
redundancy lost. |
| redundancy is lost in a mirrored |
|
| memory configuration. |
|
|
|
Memory Mirrored | Information | This event is generated when the |
redundancy regained. |
| redundancy lost or degraded |
|
| earlier is regained in a mirrored |
|
| memory configuration. |
|
|
|
Memory Spared redundancy | Warning | This event is generated when |
degraded. |
| there is a memory failure in a |
|
| spared memory configuration. |
|
|
|
Memory Spared redundancy | Critical | This event is generated when |
lost. |
| redundancy is lost in a spared |
|
| memory configuration. |
|
|
|
213