Dell 7.4 manual Possible because there is no redundancy

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 145
Image 145

Severity

Critical / Failure / Error

Cause and

Cause: A redundant virtual disk has lost redundancy. This may occur when the

Action

virtual disk suffers the failure of multiple physical disks. In this case, both the source

 

physical disk and the target disk with redundant data have failed. A rebuild is not

 

possible because there is no redundancy.

 

Action: Replace the failed disks and restore from backup.

Related Alert

Clear Alert Number: 1204

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2081

SNMP Trap

1204

Numbers

 

Event ID — 2311

Description

The firmware on the EMMs is not the same version. EMM0 %1 EMM1 %2.

Severity

Warning / Non-critical

Cause and

Cause: The firmware on the EMM modules is not the same version. It is required

Action

that both modules have the same version of the firmware. This alert may be caused

 

if you attempt to insert an EMM module that has a different firmware version than

 

an existing module. The %1 and %2 indicate a substitution variable. The text for

 

these substitution variables is displayed with the alert in the alert log and can vary

 

depending on the situation.

 

Action: Upgrade to the same version of the firmware on both EMM modules.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2090

SNMP Trap

853

Numbers

 

Event ID — 2312

Description

A power supply in the enclosure has an AC failure.

Severity

Warning / Non-critical

Cause and

Cause: The power supply has an AC failure.

Action

Action: Replace the power supply.

Related Alert

Clear Alert Number: 1003

Information

Related Alert Number: 2122, 2324

 

Local Response Agent (LRA) Number: 2090

SNMP Trap

1003

Numbers

 

145

Page 145
Image 145
Dell 7.4 manual Possible because there is no redundancy