Cause and | Cause: The physical disk enclosure is either hotter or cooler than the maximum or |
Action | minimum allowable temperature range. |
| Action: Check for factors that may cause overheating or excessive cooling. For |
| example, verify that the enclosure fan is working. You should also check the |
| thermostat settings and examine whether the enclosure is located near a heat |
| source. Make sure the enclosure has enough ventilation and that the room |
| temperature is not too hot or too cold. See the enclosure documentation for more |
| diagnostic information. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: 2091 |
SNMP Trap | 854 |
Numbers |
|
Event ID — 2114 | |
Description | A consistency check on a virtual disk has been paused (suspended). |
Severity | OK / Normal / Informational |
Cause and | Cause: The check consistency operation on a virtual disk was paused by a user. |
Action | Action: To resume the check consistency operation, |
| the tree view and select Resume Check Consistency. |
Related Alert | Clear Alert Number: 2115 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1201 |
Numbers |
|
Event ID — 2115 | |
Description | A consistency check on a virtual disk has been resumed. |
Severity | OK / Normal / Informational |
Cause and | Cause: The check consistency operation on a virtual disk has resumed processing |
Action | after being paused by a user. This alert is for informational purposes. |
| Action: None |
Related Alert | Clear Alert Number: Alert 2115 is a clear alert for alert 2114. |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1201 |
Numbers |
|
78