SNMP Trap

1204

Numbers

 

Event ID — 2082

Description

Virtual disk rebuild failed.

Severity

Critical / Failure / Error

Cause and

Cause: A physical disk included in the virtual disk has failed or is not functioning. A

Action

user may also have cancelled the rebuild.

 

Action: Replace the failed or non-functional disk. You can identify a disk that has

 

failed by locating the disk that has a red X for its status. Restart the virtual disk

 

rebuild.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2048

 

Local Response Agent (LRA) Number: 2081

SNMP Trap

1204

Numbers

 

Event ID — 2083

Description

Physical disk rebuild failed.

Severity

Critical / Failure / Error

Cause and

Cause: A physical disk included in the virtual disk has failed or is not functioning. A

Action

user may also have cancelled the rebuild.

 

Action: Replace the failed or non-functional disk. You can identify a disk that has

 

failed by locating the disk that has a red X for its status. Rebuild the virtual disk

 

rebuild.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2071

SNMP Trap

904

Numbers

 

Event ID — 2085

Description

Virtual disk check consistency completed.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None