Icon

Alert Severity

Component Status

 

 

 

 

 

temperature probe in an enclosure) has crossed

 

 

a warning threshold.

 

Critical / Failure /

A significant event that indicates actual or

 

Error

imminent loss of data or loss of function. For

 

 

example, crossing a failure threshold or a

 

 

hardware failure such as an array disk.

Server Administrator generates events based on status changes in the following sensors:

Temperature Sensor — Helps protect critical components by alerting the systems management console when temperatures become too high inside a chassis; also monitors the temperature in a variety of locations in the chassis and in attached system(s).

Fan Sensor — Monitors fans in various locations in the chassis and in attached system(s).

Voltage Sensor — Monitors voltages across critical components in various chassis locations and in attached system(s).

Current Sensor — Monitors the current (or amperage) output from the power supply (or supplies) in the chassis and in attached system(s).

Chassis Intrusion Sensor — Monitors intrusion into the chassis and attached system(s).

Redundancy Unit Sensor — Monitors redundant units (critical units such as fans, AC power cords, or power supplies) within the chassis; also monitors the chassis and attached system(s). For example, redundancy allows a second or nth fan to keep the chassis components at a safe temperature when another fan has failed. Redundancy is normal when the intended number of critical components are operating. Redundancy is degraded when a component fails, but others are still operating. Redundancy is lost when there is one less critical redundancy device than required.

Power Supply Sensor — Monitors power supplies in the chassis and in attached system(s).

Memory Prefailure Sensor — Monitors memory modules by counting the number of Error Correction Code (ECC) memory corrections.

Fan Enclosure Sensor — Monitors protective fan enclosures by detecting their removal from and insertion into the system, and by measuring how long a fan enclosure is absent from the chassis. This sensor monitors the chassis and in attached system(s).

AC Power Cord Sensor — Monitors the presence of AC power for an AC power cord.

Hardware Log Sensor — Monitors the size of a hardware log.

Processor Sensor — Monitors the processor status in the system.

Pluggable Device Sensor — Monitors the addition, removal, or configuration errors for some pluggable devices, such as memory cards.

Battery Sensor — Monitors the status of one or more batteries in the system.

SD Card Device Sensor — Monitors instrumented Secure Digital (SD) card devices in the system.

Sample Event Message Text

The following example shows the format of the event messages logged by Server Administrator.

EventID: 1000

Source: Server Administrator

Category: Instrumentation Service

Type: Information

Date and Time: Mon Oct 21 10:38:00 2002

Computer: <computer name>

Description: Server Administrator starting

20

Page 20
Image 20
Dell 7.4 manual Sample Event Message Text