Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2090

SNMP Trap

853

Numbers

 

Event ID — 2356

Description

SAS SMP Communications error %1.

Severity

Critical / Failure / Error

Cause and

Cause: The text for this alert is generated by the firmware and can vary depending

Action

on the situation. The reference to SMP in this text refers to SAS Management

 

Protocol.

 

Action: There may be a SAS topology error. See the hardware documentation for

 

information on correct SAS topology configurations. There may be problems with

 

the cables such as a loose connection or an invalid cabling configuration. See the

 

Cables Attached Correctly section for more information on checking the cables.

 

See the hardware documentation for information on correct cabling

 

configurations. Verify that the firmware is a supported version.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2061

SNMP Trap

754

Numbers

 

Event ID — 2357

Description

SAS expander error: %1.

Severity

Critical / Failure / Error

Cause and

Cause: The %1 indicates a substitution variable. The text for this substitution

Action

variable is generated by the firmware and is displayed with the alert in the alert log.

 

This text can vary depending on the situation.

 

Action: There may be a problem with the enclosure. Check the health of the

 

enclosure and its components by selecting the enclosure object in the tree view.

 

The Health subtab displays a red X or yellow exclamation point for enclosure

 

components that are Failed or Degraded. See the enclosure documentation for

 

more information.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

Local Response Agent (LRA) Number: 2061

161

Page 161
Image 161