Dell 7.4 manual Protocols SATA/SAS is not supported on the same virtual disk

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 164
Image 164

Event ID — 2366

Description

Dedicated spare imported as global due to missing arrays.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

901

Numbers

 

Event ID — 2367

Description

Rebuild is not possible because mixing of different media type (SSD/HDD) and bus

 

protocols (SATA/SAS) is not supported on the same virtual disk.

Severity

Cause and Action

Warning / Non-critical

Cause: The physical disk is using an incompatible technology.

Action: All physical disks in the virtual disk must use the same technology. You cannot use both SAS and SATA physical disks in the same virtual disk. Remove the physical disk and insert a new physical disk that uses the correct technology. If the rebuild does not start automatically after you have inserted a suitable physical disk, then run the Rebuild task.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2326

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

Event ID — 2368

Description

Severity

Cause and Action

Related Alert Information

The SCSI Enclosure Processor (SEP) has been rebooted as part of the firmware download operation and is unavailable until the operation completes.

OK / Normal / Informational

Cause: This alert is for informational purposes.

Action: None

Clear Alert Number: None

Related Alert Number: 2049, 2052, 2162, 2292

Local Response Agent (LRA) Number: None

164