Event ID — 2139

Description

Enclosure alarm disabled.

Severity

OK / Normal / Informational

Cause and

Cause: A user has disabled the enclosure alarm.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

851

Numbers

 

Event ID — 2140

Description

Dead disk segments restored.

Severity

OK / Normal / Informational

Cause and

Cause: Disk space that was formerly “dead” or inaccessible to a redundant virtual

Action

disk has been restored. This alert is for informational purposes.

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2141

Description

Physical disk dead segments removed.

Severity

OK / Normal / Informational

Cause and

Cause: Portions of the physical disk were formerly inaccessible. The disk space

Action

from these dead segments has been recovered and is now usable. Any data

 

residing on these dead segments has been lost. This alert is for informational

 

purposes.

 

Action: Check for factors that may cause overheating. For example, verify that the

 

enclosure fan is working. You should also check the thermostat settings and

 

examine whether the enclosure is located near a heat source. Make sure the

 

enclosure has enough ventilation and that the room temperature is not too hot.

 

See the physical disk enclosure documentation for more diagnostic information.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

87

Page 87
Image 87
Dell 7.4 manual Enclosure alarm disabled