Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2199

 

Local Response Agent (LRA) Number: None

SNMP Trap

1153

Numbers

 

Event ID — 2279

Description

The controller battery charge level is operating within normal limits.

Severity

OK / Normal / Informational

Cause and

Cause: This alert indicates that the battery is recharging during the battery Learn

Action

cycle. This alert is provided for informational purposes.

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1151

Numbers

 

Event ID — 2280

Description

A disk media error has been corrected.

Severity

OK / Normal / Informational

Cause and

Cause: A disk media error was detected while the controller was completing a

Action

background task. A bad disk block was identified. The disk block has been

 

remapped.

 

Action: Consider replacing the disk. If you receive this alert frequently, be sure to

 

replace the disk. You should also routinely back up your data.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2281

Description

Virtual disk has inconsistent data.

Severity

OK / Normal / Informational

Cause and

Cause: The virtual disk has inconsistent data. This may be caused when a power

Action

loss or system shutdown occurs while data is being written to the virtual disk. This

 

alert is for informational purposes.