Dell 7.4 manual Supply unit or it is defective

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 149
Image 149

Severity

Informational

Cause and

Cause: The power supply unit is switched off. Either a user switched off the power

Action

supply unit or it is defective.

 

Action: Check if the power switch is turned off. If it is turned off, turn it on. If the

 

problem persists, check if the power cord is attached and functional. If the problem

 

is still not corrected or if the power switch is already turned on, replace the power

 

supply unit.

Related Alert

Clear Alert Number: 2323

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2091

SNMP Trap

1001

Numbers

 

Event ID — 2323

Description

The power supply is switched on.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Status: Alert 2323 is a clear alert for alerts 2313 and 2322.

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1001

Numbers

 

Event ID — 2324

Description

The AC power supply cable has been removed.

Severity

Critical / Failure / Error

Cause and

Cause: The power cable may be pulled out or removed. The power cable may also

Action

have overheated and become warped and nonfunctional.

 

Action: Replace the power cable.

Related Alert

Clear Alert Number: 2325

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2091

SNMP Trap

1004

Numbers

 

149

Page 149
Image 149
Dell 7.4 manual Supply unit or it is defective