Dell 7.4 manual Automatic System Recovery ASR action was performed Action

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 28
Image 28

Event ID — 1002

Description A system BIOS update has been scheduled for the next reboot

SeverityInformation

Cause

The user has chosen to update the flash basic input/output system (BIOS).

Event ID – 1003

Description

A previously scheduled system BIOS update has been canceled

Severity

Information

Cause

The user decides to cancel the flash BIOS update, or an error occurs during the

 

flash.

Event ID — 1004

Description

Thermal shutdown protection has been initiated

Severity

Error

Cause

This message is generated when a system is configured for thermal shutdown due

 

to an error event. If a temperature sensor reading exceeds the error threshold for

 

which the system is configured, the operating system shuts down and the system

 

powers off. This event may also be initiated on certain systems when a fan

 

enclosure is removed from the system for an extended period of time.

Event ID — 1005

Description

SMBIOS data is absent

Severity

Error

Cause

The system does not contain the required systems management BIOS version 2.2

 

or higher, or the BIOS is corrupted.

Event ID — 1006

Description

Automatic System Recovery (ASR) action was performed Action

 

performed was: <Action>

 

Date and time of action:<Date and time>

Severity

Error

Cause

This message is generated when an automatic system recovery action is performed

 

due to a hung operating system. The action performed and the time of action is

 

provided.

28

Page 28
Image 28
Dell 7.4 manual Automatic System Recovery ASR action was performed Action