SNMP Trap

1201

Numbers

 

Event ID — 2076

Description

Virtual disk Check Consistency failed.

Severity

Critical / Failure / Error

Cause and

Cause: AA physical disk included in the virtual disk failed or there is an error in the

Action

parity information. A failed physical disk can cause errors in parity information.

 

Action: Replace the failed physical disk. You can identify which disk has failed by

 

locating the disk that has a red “X” for its status. Rebuild the physical disk. When

 

finished, restart the check consistency operation.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2081

SNMP Trap

1204

Numbers

 

Event ID — 2077

Description

Virtual disk format failed.

Severity

Critical / Failure / Error

Cause and

Cause: A physical disk included in the virtual disk failed.

Action

Action: Replace the failed physical disk. You can identify which physical disk has

 

failed by locating the disk that has a red X for its status. Rebuild the physical disk.

 

When finished, restart the virtual disk format operation.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2081

SNMP Trap

1204

Numbers

 

Event ID — 2079

Description

Virtual disk initialization failed.

Severity

Critical / Failure / Error

Cause and

Cause: A physical disk included in the virtual disk has failed or a user has cancelled

Action

the initialization.

 

Action: If a physical disk has failed, then replace the physical disk

66

Page 66
Image 66
Dell 7.4 manual Virtual disk Check Consistency failed