Event Message | Severity | Cause |
|
|
|
Device option ROM on | Critical | This event is generated when the |
mezzanine card <number> |
| PCI device option ROM for a NIC |
failed to support Link |
| does not support link tuning or |
Tuning or FlexAddress. |
| the Flex addressing feature. |
Failed to program virtual | Critical | This event is generated when |
MAC address on a |
| BIOS fails to program virtual MAC |
component at bus <bus> |
| address on the given NIC device. |
device <device> function |
|
|
<function>. |
|
|
Failed to get Link Tuning | Critical | This event is generated when |
or FlexAddress data from |
| BIOS could not obtain virtual |
iDRAC. |
| MAC address or Link Tuning data |
|
| from iDRAC. |
|
|
|
An unknown system | Critical | This event is generated when an |
hardware failure |
| unknown hardware failure is |
detected. |
| detected. |
POST fatal error <error | Critical | This event is generated when a |
description> |
| fatal error occurs during system |
|
| boot. For more information, see |
|
| POST Code Errors. |
|
|
|
POST Code Table
The following table lists the POST Code errors that are generated when a fatal error occurs during system boot.
Table 17. POST Code Table
Fatal Error Code | Description | Cause |
|
|
|
80 | No memory detected. | This error code implies that no |
|
| memory is installed. |
|
|
|
81 | Memory detected but is not | This error code indicates |
| configurable. | memory configuration error that |
|
| could be a result of bad memory, |
|
| mismatched memory or bad |
|
| socket. |
|
|
|
82 | Memory configured but not | This error code indicates |
| usable. | memory |
|
|
|
83 | System BIOS shadow failure. | This error code indicates system |
|
| BIOS shadow failure. |
|
|
|
84 | CMOS failure. | This error code indicates that |
|
| CMOS RAM is not working. |
|
|
|
224