Dell 7.4 manual Chassis Intrusion Messages

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 39
Image 39

Cause

A current sensor in the specified system exceeded its failure threshold. The sensor

 

location, chassis location, previous state, and current sensor value are provided.

Event ID — 1205

 

Description

Current sensor

detected a non-recoverable value Sensor

 

location: <Location in chassis>

 

Chassis location: <Name of chassis>

 

Previous state

was: <State>

 

If sensor type

is not discrete:

 

Current sensor

value (in Amps): <Reading> OR

 

Current sensor

value (in Watts): <Reading>

 

If sensor type

is discrete:

 

Discrete voltage state: <State>

Severity

Error

 

Cause

A current sensor in the specified system detected an error from which it cannot

 

recover. The sensor location, chassis location, previous state, and current sensor

 

value are provided.

 

Chassis Intrusion Messages

The chassis intrusion messages listed are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis.

Event ID — 1251

Description

Chassis intrusion sensor value unknown Sensor location:

 

<Location in chassis>

 

Chassis location: <Name of chassis>

 

Previous state was: <State>

 

Chassis intrusion state: <Intrusion state>

Severity

Warning

Cause

A chassis intrusion sensor in the specified system could not obtain a reading. The

 

sensor location, chassis location, previous state, and chassis intrusion state are

 

provided.

Event ID — 1252

Description

Chassis intrusion returned to normal Sensor location: <Location

 

in chassis>

Chassis location: <Name of chassis>

Previous state was: <State>

39

Page 39
Image 39