Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

 

Local Response Agent (LRA) Number: 2090

SNMP Trap

853

Numbers

 

Event ID — 2299

Description

Bad PHY %1

Severity

Critical / Failure / Error

Cause and

Cause: There is a problem with a physical connection or PHY. The %1 indicates a

Action

substitution variable. The text for this substitution variable is displayed with the alert

 

in the alert log and can vary depending on the situation.

 

Action: Contact your technical support.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2091

SNMP Trap

854

Numbers

 

Event ID — 2300

Description

The enclosure is unstable.

Severity

Critical / Failure / Error

Cause and

Cause: The controller is not receiving a consistent response from the enclosure.

Action

There could be a firmware problem or an invalid cabling configuration. If the cables

 

are too long, they degrade the signal.

 

Action: Power down all enclosures attached to the system and reboot the system.

 

If the problem persists, upgrade the firmware to the latest supported version. You

 

can download the most current version of the driver and firmware from the

 

support site. Make sure the cable configuration is valid. See the hardware

 

documentation for valid cabling configurations.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2091

SNMP Trap

854

Numbers

 

Event ID — 2301

Description

The enclosure has a hardware error.

141

Page 141
Image 141
Dell 7.4 manual Bad PHY %1