Event ID — 2287

Description

Protection policy has been changed.

Severity

OK / Normal / Informational

Cause and

Cause: A new protection policy has been created / existing protection policy has

Action

been modified.

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2384

 

Local Response Agent (LRA) Number: None

SNMP Trap

101

Numbers

 

Event ID — 2288

Description

The patrol read has resumed.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

751

Numbers

 

Event ID — 2289

Description

Multi-bit ECC error on controller DIMM.

Severity

Critical / Failure / Error

Cause and

Cause: An error involving multiple bits has been encountered during a read or write

Action

operation. The error correction algorithm recalculates parity data during read and

 

write operations. If an error involves only a single bit, it may be possible for the

error correction algorithm to correct the error and maintain parity data. An error involving multiple bits, however, usually indicates data loss. In some cases, if the multi-bit error occurs during a read operation, the data on the disk may be OK. If the multi-bit error occurs during a write operation, data loss has occurred.

Action: Replace the dual in-line memory module (DIMM). The DIMM is a part of the controller battery pack. See your hardware documentation for information on replacing the DIMM. You may need to restore data from backup.

137