| If in configuration error state: |
| Configuration error type:<type of configuration error> |
Severity | Error |
Cause | A power supply has been disconnected or has failed. The sensor location, chassis |
| location, previous state, power supply type, additional power supply status, and |
| configuration error type information are provided. |
Memory Device Messages
The memory device messages listed provides status and warning information for memory modules present in a particular system. Memory devices determine health status by monitoring the ECC memory correction rate and the type of memory events that have occurred.
NOTE: A critical status does not always indicate a system failure or loss of data. In some instances, the system has exceeded the ECC correction rate. Although the system continues to function, you should perform system maintenance as described.
NOTE: The <status> can be either critical or
Event ID — 1400
Description | Memory device status is <status> |
| Memory device location: <location in chassis> |
| Possible memory module event cause: <list of causes> |
Severity | Informational |
Cause | Memory device monitoring has been disabled. The memory module may not be |
| correctly seated, wrongly configured, or has failed. |
Event ID — 1401
Description | Memory device status is <status> |
| Memory device location: <location in chassis> |
| Possible memory module event cause: <list of causes> |
Severity | Informational |
Cause | Memory device status is unknown. The memory module may not be correctly |
| seated, wrongly configured, or has failed. |
Event ID — 1402
Description Memory device status is <status>
Memory device location: <location in chassis>
Possible memory module event cause: <list of causes>
SeverityInformational
44