Dell 7.4 manual Memory Device Messages

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 44
Image 44

 

If in configuration error state:

 

Configuration error type:<type of configuration error>

Severity

Error

Cause

A power supply has been disconnected or has failed. The sensor location, chassis

 

location, previous state, power supply type, additional power supply status, and

 

configuration error type information are provided.

Memory Device Messages

The memory device messages listed provides status and warning information for memory modules present in a particular system. Memory devices determine health status by monitoring the ECC memory correction rate and the type of memory events that have occurred.

NOTE: A critical status does not always indicate a system failure or loss of data. In some instances, the system has exceeded the ECC correction rate. Although the system continues to function, you should perform system maintenance as described.

NOTE: The <status> can be either critical or non-critical.

Event ID — 1400

Description

Memory device status is <status>

 

Memory device location: <location in chassis>

 

Possible memory module event cause: <list of causes>

Severity

Informational

Cause

Memory device monitoring has been disabled. The memory module may not be

 

correctly seated, wrongly configured, or has failed.

Event ID — 1401

Description

Memory device status is <status>

 

Memory device location: <location in chassis>

 

Possible memory module event cause: <list of causes>

Severity

Informational

Cause

Memory device status is unknown. The memory module may not be correctly

 

seated, wrongly configured, or has failed.

Event ID — 1402

Description Memory device status is <status>

Memory device location: <location in chassis>

Possible memory module event cause: <list of causes>

SeverityInformational

44

Page 44
Image 44
Dell 7.4 manual Memory Device Messages