SNMP Trap

1151

Numbers

 

Event ID — 2173

Description

Unsupported configuration detected. The SCSI rates of the enclosure management

 

modules (EMMs) are not the same. EMM 0 % 1 EMM 1 % 2

Severity

Cause and Action

Related Alert Information

SNMP Trap Numbers

Warning / Non-critical

Cause: An unsupported configuration was detected.

Action: Replace one of the EMMs with the matching SCSI rate EMM.

Clear Alert Number: None

Related Alert Number: None

Local Response Agent (LRA) Number: 2090

853

Event ID — 2174

Description

The controller battery has been removed.

Severity

Warning / Non-critical

Cause and

Cause: The controller cannot communicate with the battery. The battery may be

Action

removed, or the contact point between the controller and the battery may be burnt

 

or corroded.

 

Action: Replace the battery if it has been removed. If the contact point between

 

the battery and the controller is burnt or corroded, you must replace either the

 

battery or the controller, or both. See the hardware documentation for information

 

on how to safely access, remove, and replace the battery.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2188, 2318

 

Local Response Agent (LRA) Number: 2100

SNMP Trap

1153

Numbers

 

Event ID — 2175

Description

The controller battery has been replaced.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

99

Page 99
Image 99
Dell 7.4 manual Snmp Trap 1151 Numbers