Severity | OK / Normal / Informational |
Cause and | Cause: The %1 indicates a substitution variable. The text for this substitution |
Action | variable is generated by the controller and is displayed with the alert in the alert log. |
| This text can vary depending on the situation. This alert is for informational |
| purposes. |
| Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 751 |
Numbers |
|
Event ID — 2331 | |
Description | A bad disk block has been reassigned. |
Severity | OK / Normal / Informational |
Cause and | Cause: The disk has a bad block. Data has been readdressed to another disk block |
Action | and no data loss has occurred. |
| Action: Monitor the disk for other alerts or indications of poor health. For example, |
| you may receive alert 2306. Replace the disk if you suspect there is a problem. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 901 |
Numbers |
|
Event ID — 2332 | |
Description | A controller hot plug has been detected. |
Severity | OK / Normal / Informational |
Cause and | Cause: This alert is for informational purposes. |
Action | Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 751 |
Numbers |
|
152