Severity

OK / Normal / Informational

Cause and

Cause: The %1 indicates a substitution variable. The text for this substitution

Action

variable is generated by the controller and is displayed with the alert in the alert log.

 

This text can vary depending on the situation. This alert is for informational

 

purposes.

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

751

Numbers

 

Event ID — 2331

Description

A bad disk block has been reassigned.

Severity

OK / Normal / Informational

Cause and

Cause: The disk has a bad block. Data has been readdressed to another disk block

Action

and no data loss has occurred.

 

Action: Monitor the disk for other alerts or indications of poor health. For example,

 

you may receive alert 2306. Replace the disk if you suspect there is a problem.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

901

Numbers

 

Event ID — 2332

Description

A controller hot plug has been detected.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

751

Numbers

 

152

Page 152
Image 152