Cause and Action

Related Alert Information

SNMP Trap Numbers

Cause: One or more of the enclosure components has failed.

For example, a fan or power supply may have failed. Although the enclosure is currently operational, the failure of additional components could cause the enclosure to fail.

Action: Identify and replace the failed component. To identify the failed component, select the enclosure in the tree view and click the Health subtab. Any failed component is identified with a red X on the enclosure’s Health subtab. Alternatively, you can select the Storage object and click the Health subtab.

The controller status displayed on the Health subtab indicates whether a controller has a Failed or Degraded component.

See the enclosure documentation for information on replacing enclosure components and for other diagnostic information.

Clear Alert Number: 2124

Related Alert Number: 2048

Local Response Agent (LRA) Number: 2090

1305

Event ID — 2123

Description

Redundancy lost.

Severity

Warning / Non-critical

Cause and

Cause: A virtual disk or an enclosure has lost data redundancy. In the case of a

Action

virtual disk, one or more physical disks included in the virtual disk have failed. Due

 

to the failed physical disk or disks, the virtual disk is no longer maintaining

 

redundant (mirrored or parity) data. The failure of an additional physical disk results

 

in lost data. In the case of an enclosure, more than one enclosure component has

 

failed. For example, the enclosure may have suffered the loss of all fans or all

 

power supplies.

 

Action: Identify and replace the failed components. To identify the failed

 

component, select the Storage object and click the Health subtab. The controller

 

status displayed on the Health subtab indicates whether a controller has a Failed or

 

Degraded component.

 

Click the controller that displays a Warning or Failed status. This action displays the

 

controller Health subtab which displays the status of the individual controller

 

components. Continue clicking the components with a Warning or Health status

 

until you identify the failed component.

 

See the online help for more information. See the enclosure documentation for

 

information on replacing enclosure components and for other diagnostic

 

information.

Related Alert

Clear Alert Number: 2353

Information

Related Alert Number: 2112

 

Local Response Agent (LRA) Number: 2090

81

Page 81
Image 81
Dell 7.4 manual Redundancy lost