Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1201

Numbers

 

Event ID — 2120

Description

Enclosure firmware mismatch.

Severity

Warning / Non-critical

Cause and

Cause: The firmware on the EMM is not the same version. It is required that both

Action

modules have the same version of the firmware. This alert may be caused when a

 

user attempts to insert an EMM module that has a different firmware version than

 

an existing module.

 

Action: Download the same version of the firmware to both EMM modules.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2090

SNMP Trap

853

Numbers

 

Event ID — 2121

Description

Device returned to normal.

Severity

OK / Normal / Informational

Cause and

Cause: A device that was previously in an error state has returned to a normal state.

Action

For example, if an enclosure became too hot and subsequently cooled down, you

 

may receive this alert. This alert is for informational purposes.

 

Action: None

Related Alert

Clear Alert Number: Alert 2121 is a clear alert for alert 2048.

Information

Related Alert Number: 2050, 2065, 2158

 

Local Response Agent (LRA) Number: None

SNMP Trap

752,802, 852, 902, 952, 1002,1052, 1102, 1152, 1202

Numbers

 

Event ID — 2122

Description

Redundancy degraded.

Severity

Warning / Non-critical

80