Event ID — 2325

Description

The power supply cable has been inserted.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Status: Alert 2325 is a clear alert for alerts 2324 and 2312.

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1001

Numbers

 

Event ID — 2326

Description

A foreign configuration has been detected.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes. The controller has physical disks

Action

that were moved from another controller. These physical disks contain virtual disks

 

that were created on the other controller. See the Import Foreign Configuration

 

and Clear Foreign Configuration section in the Server Administrator Storage

 

Management User’s Guide for more information.

 

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

751

Numbers

 

Event ID — 2327

Description

The NVRAM has corrupted data. The controller is reinitializing the NVRAM.

Severity

Warning / Non-critical

Cause and

Cause: The nonvolatile random access memory (NVRAM) is corrupt. This may

Action

occur after a power surge, a battery failure, or for other reasons. The controller is

 

reinitializing the NVRAM. The controller properties reset to the default settings after

 

the reinitialization is complete.

NOTE: The controller is taking the required corrective action. If this alert is generated often (such as during each reboot), replace the controller.

150

Page 150
Image 150
Dell 7.4 manual Management User’s Guide for more information