Cause and Action

Related Alert Information

SNMP Trap Numbers

Hardware RAID: Cause and Action

Cause: You are attempting to rebuild data that resides on a defective disk.

Action: Replace the source disk and restore from backup.

Software RAID:

Perform a backup with the Verify option.

If the file backup fails, try to restore the failed file from a previous backup.

When the backup with the Verify option is complete without any errors, delete the Virtual Disk.

Recreate a new Virtual Disk with new drives.

Restore the data from backup.

Clear Alert Number: None

Related Alert Number: 2195, 2346

Local Response Agent (LRA) Number: 2071

904

Event ID — 2348

Description

The rebuild failed due to errors on the target physical disk.

Severity

Critical / Failure / Error

Cause and

Cause:You are attempting to rebuild data on a disk that is defective.

Action

Action: Replace the target disk. If a rebuild does not automatically start after

 

replacing the disk, initiate the Rebuild task. You may need to assign the new disk as

 

a hot spare to initiate the rebuild.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2195, 2346

 

Local Response Agent (LRA) Number: 2071

SNMP Trap

904

Numbers

 

Event ID — 2349

Description

A bad disk block could not be reassigned during a write operation.

Severity

Critical / Failure / Error

Cause and

Cause: A write operation could not complete because the disk contains bad disk

Action

blocks that could not be reassigned. Data loss may have occurred and data

 

redundancy may also be lost.

 

Action: Replace the disk.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2346

158

Page 158
Image 158
Dell 7.4 manual Rebuild failed due to errors on the target physical disk