Cause and Action
Related Alert Information
SNMP Trap Numbers
Hardware RAID: Cause and Action
Cause: You are attempting to rebuild data that resides on a defective disk.
Action: Replace the source disk and restore from backup.
Software RAID:
•Perform a backup with the Verify option.
•If the file backup fails, try to restore the failed file from a previous backup.
•When the backup with the Verify option is complete without any errors, delete the Virtual Disk.
•Recreate a new Virtual Disk with new drives.
•Restore the data from backup.
Clear Alert Number: None
Related Alert Number: 2195, 2346
Local Response Agent (LRA) Number: 2071
904
Event ID — 2348
Description | The rebuild failed due to errors on the target physical disk. |
Severity | Critical / Failure / Error |
Cause and | Cause:You are attempting to rebuild data on a disk that is defective. |
Action | Action: Replace the target disk. If a rebuild does not automatically start after |
| replacing the disk, initiate the Rebuild task. You may need to assign the new disk as |
| a hot spare to initiate the rebuild. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2195, 2346 |
| Local Response Agent (LRA) Number: 2071 |
SNMP Trap | 904 |
Numbers |
|
Event ID — 2349 | |
Description | A bad disk block could not be reassigned during a write operation. |
Severity | Critical / Failure / Error |
Cause and | Cause: A write operation could not complete because the disk contains bad disk |
Action | blocks that could not be reassigned. Data loss may have occurred and data |
| redundancy may also be lost. |
| Action: Replace the disk. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2346 |
158