Event Message

Severity

Cause

 

 

 

Fan <number> RPM is

Information

The speed of the specified fan is

within range.

 

operating in a normal range.

Fan <number> is removed.

Critical

A required fan was removed.

Fan <number> was

Information

A fan was added.

inserted.

 

 

Fan <number> is present.

Information

The total number of fans present.

Fan <number> is absent.

Critical

A required fan is missing.

The fans are redundant.

Information

One or more fans may have

 

 

started functioning or installed

 

 

and the redundancy has been

 

 

regained.

 

 

 

Fan redundancy is lost.

Critical

One or more required fans may

 

 

have failed or removed and

 

 

hence, the redundancy was lost.

 

 

 

Fan redundancy is

Warning

One or more fans may have

degraded.

 

failed or removed and hence, the

 

 

redundancy has been degraded.

 

 

 

Processor Status Events

The processor status messages monitor the functionality of the processors in a system. These messages provide processor health and warning information of a system.

Table 8. Processor Status Events

Event Message

Severity

Cause

 

 

 

<Processor Entity> status

Critical

IERR internal error generated by

processor sensor IERR,

 

the <Processor Entity>. This

where <Processor Entity>

 

event is generated due to

is the processor that

 

processor internal error.

generated the event. For

 

 

example, PROC for a

 

 

single processor system

 

 

and PROC # for

 

 

multiprocessor system.

 

 

<Processor Entity> status

Critical

The processor generates this

processor sensor Thermal

 

event before it shuts down

Trip.

 

because of excessive heat

 

 

caused by lack of cooling or heat

 

 

synchronization.

 

 

 

<Processor Entity> status

Information

This event is generated when a

processor sensor

 

processor recovers from the

recovered from IERR.

 

internal error.

205

Page 205
Image 205
Dell 7.4 manual Processor Status Events, Fans are redundant