SNMP Trap

1201

Numbers

 

Event ID — 2384

Description

The Warning level set for the hot spare protection policy is violated for the Virtual

 

Disk.

Severity

Warning / Non-critical

Cause and

Cause: The number of physical disks you specified for the hot spare protection

Action

policy is violated.

 

Action: Reassign the number of hot spares as specified in the protection policy for

 

that RAID level.

Related Alert

Clear Alert Number: 2195

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1203

Numbers

 

Event Id — 2385

Description

The Critical level set for the hot spare protection policy is violated for the Virtual

 

Disk.

Severity

Critical / Failure / Error

Cause and

Cause: The number of physical disks you specified for the hot spare protection

Action

policy is violated.

 

Action: Reassign the number of hot spares as specified in the protection policy for

 

that RAID level.

Related Alert

Clear Alert Number: 2195

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1204

Numbers

 

Event ID — 2386

Description

Drive could not be assigned as Dedicated Hot Spare.

Severity

Informational

Cause and

Cause: The assignment of a Dedicated Hot Spare fails as the disk is invalid.

Action

Action: None.

170

Page 170
Image 170
Dell 7.4 manual Drive could not be assigned as Dedicated Hot Spare