SNMP Trap | 1201 |
Numbers |
|
Event ID — 2384 | |
Description | The Warning level set for the hot spare protection policy is violated for the Virtual |
| Disk. |
Severity | Warning / |
Cause and | Cause: The number of physical disks you specified for the hot spare protection |
Action | policy is violated. |
| Action: Reassign the number of hot spares as specified in the protection policy for |
| that RAID level. |
Related Alert | Clear Alert Number: 2195 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1203 |
Numbers |
|
Event Id — 2385 | |
Description | The Critical level set for the hot spare protection policy is violated for the Virtual |
| Disk. |
Severity | Critical / Failure / Error |
Cause and | Cause: The number of physical disks you specified for the hot spare protection |
Action | policy is violated. |
| Action: Reassign the number of hot spares as specified in the protection policy for |
| that RAID level. |
Related Alert | Clear Alert Number: 2195 |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1204 |
Numbers |
|
Event ID — 2386 | |
Description | Drive could not be assigned as Dedicated Hot Spare. |
Severity | Informational |
Cause and | Cause: The assignment of a Dedicated Hot Spare fails as the disk is invalid. |
Action | Action: None. |
170