SNMP Trap

904

Numbers

 

Event ID — 2108

Description

SMART warning.

Severity

Warning / Non-critical

Cause and

Cause: A disk has received a SMART alert (predictive failure). The disk is likely to fail

Action

in the near future.

 

Action: Replace the disk that has received the SMART alert. If the physical disk is a

 

member of a non-redundant virtual disk, then back up the data before replacing

 

the disk.

 

CAUTION: Removing a physical disk that is included in a non-redundant

 

virtual disk causes the virtual disk to fail and may cause data loss.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

Event ID — 2109

Description

SMART warning temperature.

Severity

Warning / Non-critical

Cause and

Cause: A disk has reached an unacceptable temperature and received a SMART

Action

alert (predictive failure). The disk is likely to fail in the near future.

 

Action 1: Determine why the physical disk has reached an unacceptable

 

temperature. A variety of factors can cause the excessive temperature. For

 

example, a fan may have failed, the thermostat may be set too high, or the room

 

temperature may be too hot or cold. Verify that the fans in the server or enclosure

 

are working. If the physical disk is in an enclosure, you should check the

 

thermostat settings and examine whether the enclosure is located near a heat

 

source.

Make sure the enclosure has enough ventilation and that the room temperature is not too hot. See the physical disk enclosure documentation for more diagnostic information.

Action 2 : If you cannot identify why the disk has reached an unacceptable temperature, then replace the disk. If the physical disk is a member of a non- redundant virtual disk, then back up the data before replacing the disk.

CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes the virtual disk to fail and may cause data loss.

76

Page 76
Image 76
Dell 7.4 manual Smart warning