Dell 7.4 manual Nvram has corrupt data

Models: 7.4

1 232
Download 232 pages 10.61 Kb
Page 151
Image 151

Related Alert

Clear Alert Number: None

Information

Related Alert Number: 2266

 

Local Response Agent (LRA) Number: 2060

SNMP Trap

753

Numbers

 

Event ID — 2328

Description

The NVRAM has corrupt data.

Severity

Warning / Non-critical

Cause and

Cause: The NVRAM has corrupt data. The controller is unable to correct the

Action

situation.

 

Action: Replace the controller.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 20601

SNMP Trap

753

Numbers

 

Event ID — 2329

Description

SAS port report: %1

Severity

Warning / Non-critical

Cause and

Cause: The text for this alert is generated by the controller and can vary depending

Action

on the situation. The %1 indicates a substitution variable. The text for this

 

substitution variable is generated by the controller and is displayed with the alert in

 

the alert log. This text can vary depending on the situation.

 

Action: Run the PHY integrity test diagnostic. Make sure the cables are attached

 

securely. If the problem persists, replace the cable with a valid cable according to

 

SAS specifications. If the problem still persists, you may need to replace some

 

devices such as the controller or EMM. See the hardware documentation for more

 

information.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2060

SNMP Trap

753

Numbers

 

Event ID — 2330

Description

SAS port report: %1

151

Page 151
Image 151
Dell 7.4 manual Nvram has corrupt data