Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2081

SNMP Trap

1204

Numbers

 

Event ID — 2080

Description

Physical disk initialization failed.

Severity

Critical / Failure / Error

Cause and

Cause: The physical disk has failed or is not functioning.

Action

Action: Replace the failed or non-functional disk. You can identify a disk that has

 

failed by locating the disk that has a red “X” for its status. Restart the initialization.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2071

SNMP Trap

904

Numbers

 

Event ID — 2081

Description

Severity

Cause and Action

Related Alert Information

Virtual disk reconfiguration failed.

Critical / Failure / Error

Hardware RAID:

Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have cancelled the reconfiguration.

Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the disk that displays a red X in the status field.

If the physical disk is part of a redundant array, then rebuild the physical disk. When finished, restart the reconfiguration.

Software RAID:

Perform a backup with the Verify option.

If the file backup fails, try to restore the failed file from a previous backup.

When the backup with the Verify option is complete without any errors, delete the Virtual Disk.

Recreate a new Virtual Disk with new drives.

Restore the data from backup.