Event ID — 2056
Description | Virtual disk failed. |
Severity | Critical / Failure / Error |
Cause and | Cause: One or more physical disks included in the virtual disk have failed. If the |
Action | virtual disk is |
| of a single physical disk can cause the virtual disk to fail. If the virtual disk is |
| redundant, then more physical disks have failed than can be rebuilt using mirrored |
| or parity information. |
| Action: Create a new virtual disk and restore from a backup. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2129, 2346 |
| Local Response Agent (LRA) Number: 2081 |
SNMP Trap | 1204 |
Numbers |
|
Event ID — 2057 | |
Description | Virtual disk degraded. |
Severity | Warning / |
Cause and | Cause 1: This alert message occurs when a physical disk included in a redundant |
Action | virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity |
| information) and only one physical disk has failed, the virtual disk can be rebuilt. |
| Action 1: Replace the failed drive. Rebuild of the virtual disk starts automatically. |
| NOTE: If you put the drive in a different slot, you need to assign it as a hot |
| spare for the rebuild to start automatically. |
| If you put the drive in a different slot, you need to assign it as a hot spare for the |
| rebuild to start automatically. |
| Cause 2: A physical disk in the disk group has been removed. |
| Action 2: If a physical disk was removed from the disk group, either replace the disk |
| or restore the original disk. You can identify which disk has been removed by |
| locating the disk that has a red “X” for its status. Perform a rescan after replacing |
| the disk. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2123, 2129, 2346 |
| Local Response Agent (LRA) Number: 2080 |
SNMP Trap | 1203 |
Numbers |
|
61