Event Message | Severity | Cause |
|
|
|
The temperature for power | Critical | Temperature of specified power |
supply <number> is |
| supply entered into critical state. |
outside of range. |
|
|
An under voltage fault | Critical | The specified power supply |
detected on power supply |
| detected inefficient voltage. |
<number>. |
|
|
An over voltage fault | Critical | The specified power supply |
detected on power supply |
| detected an over voltage |
<number>. |
| condition. |
An over current fault | Crotoca; | The specified power supply |
detected on power supply |
| detected an over current |
<number>. |
| condition. |
Fan failure detected on | Critical | The specified power supply fan |
power supply <number>. |
| has failed. |
Communication has been | Information | This event is generated when the |
restored to power supply |
| power supply has recovered |
<number>. |
| from an earlier communication |
|
| problem. |
|
|
|
A power supply wattage | Critical | This event is generated when |
mismatch is detected; |
| there is more than one power |
power supply <number> is |
| supplies in the system and the |
rated for <value> watts. |
| power supply wattage do not |
|
| match. |
|
|
|
Power supply <number> | Information | This event is generated when the |
wattage mismatch |
| power supply has recovered |
corrected. |
| from an earlier power supply |
|
| wattage mismatch. |
|
|
|
Power supply redundancy | Critical | Power supply redundancy is lost |
is lost. |
| if only one power supply is |
|
| functional. |
|
|
|
Power supply redundancy | Warning | Power supply redundancy is |
is degraded. |
| degraded if one of the power |
|
| supply sources is removed or |
|
| failed. |
|
|
|
The power supplies are | Information | This event is generated if the |
redundant. |
| power supply has been |
|
| reconnected or replaced. |
|
|
|
210