Event ID — 2162

Description

Communication regained.

Severity

OK / Normal / Informational

Cause and

Cause: Communication with an enclosure has been restored. This alert is for

Action

informational purposes.

 

Action: None

Related Alert

Clear Alert Number: Alert 2162 is a clear alert for alerts 2137 and 2292.

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

851

Numbers

 

Event ID — 2163

Description

Rebuild completed with errors.

Severity

OK / Normal / Informational

Cause and

Cause: During a rebuild one or more blocks of data was not recoverable due to

Action

missing parity information. Some data loss may have occurred.

 

Action: Perform a check to verify the built array. Any files that are impacted should

 

be restored from a backup. See the Storage Management online help for more

 

information.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: 2071

SNMP Trap

904

Numbers

 

Event ID — 2164

Description

See the Readme file for a list of validated controller driver versions.

Severity

OK / Normal / Informational

Cause and

Cause: Storage Management is unable to determine whether the system has the

Action

minimum required versions of the RAID controller drivers. This alert is for

 

informational purposes.

 

Action: See the Readme file for driver and firmware requirements. In particular, if

 

Storage Management experiences performance problems, you should verify that

 

you have the minimum supported versions of the drivers and firmware installed.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

95

Page 95
Image 95
Dell 7.4 manual Communication regained