Event ID — 2415
Description | Controller battery is discharging. |
Severity | Informational |
Cause and | Cause: The battery learn cycle has started. |
Action | Action: None |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 1151 |
Numbers |
|
Event ID — 2416 | |
Description | Disk medium error detected. |
Severity | Warning / |
Cause and | Cause: A part of the physical disk is damaged. |
Action | Action: None. |
Related Alert | Clear Alert Number: None |
Information | Related Alert Number: None |
| Local Response Agent (LRA) Number: None |
SNMP Trap | 903 |
Numbers |
|
Event ID — 2417 | |
Description | There is an unrecoverable medium error detected on virtual disk. |
Severity | Critical / Failure / Error |
Cause and | Cause: Unrecoverable medium error found on one or more member physical disks |
Action | of a virtual disk. |
| Action: Perform a backup of the virtual disk with the Verify option selected. If the |
| Backup operation is successful, it indicates that the |
| not affect user data. |
If the Backup operation fails, restore the file from a previous backup. After restoring the file, run check consistency operation:
• If the consistency check is successful, no further action is required.
• If the consistency check finds and unrecoverable medium error, it means that the medium error is located in
179