Event ID — 2415

Description

Controller battery is discharging.

Severity

Informational

Cause and

Cause: The battery learn cycle has started.

Action

Action: None

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

1151

Numbers

 

Event ID — 2416

Description

Disk medium error detected.

Severity

Warning / Non-critical

Cause and

Cause: A part of the physical disk is damaged.

Action

Action: None.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

903

Numbers

 

Event ID — 2417

Description

There is an unrecoverable medium error detected on virtual disk.

Severity

Critical / Failure / Error

Cause and

Cause: Unrecoverable medium error found on one or more member physical disks

Action

of a virtual disk.

 

Action: Perform a backup of the virtual disk with the Verify option selected. If the

 

Backup operation is successful, it indicates that the un-recoverable medium did

 

not affect user data.

If the Backup operation fails, restore the file from a previous backup. After restoring the file, run check consistency operation:

• If the consistency check is successful, no further action is required.

• If the consistency check finds and unrecoverable medium error, it means that the medium error is located in non-user data. No further action is required as, writing data to the location of the medium error fixes the problem.