Event ID — 2092

Description

Physical disk rebuild completed.

Severity

OK / Normal / Informational

Cause and

Cause: This alert is for informational purposes.

Action

Action: None

Related Alert

Clear Alert Number: Alert 2092 is a clear alert for alert 2065.

Information

Related Alert Number: None

 

Local Response Agent (LRA) Number: None

SNMP Trap

901

Numbers

 

Event ID — 2094

Description

Predictive Failure reported.

Severity

Warning / Non-critical

Cause and

Cause: The physical disk is predicted to fail. Many physical disks contain Self

Action

Monitoring Analysis and Reporting Technology (SMART). When enabled, SMART

 

monitors the health of the disk based on indications such as the number of write

 

operations that have been performed on the disk.

 

Action: Replace the physical disk. Even though the disk may not have failed yet, it is

 

strongly recommended that you replace the disk.

 

If this disk is part of a redundant virtual disk, perform the Offline task on the disk;

 

replace the disk; the rebuild starts automatically.

 

NOTE: If you put the drive in a different slot, you need to assign it as a hot

 

spare for the rebuild to start automatically.

 

If this disk is a hot spare, then unassign the hot spare; perform the Prepare to

 

Remove task on the disk; replace the disk; and assign the new disk as a hot spare.

 

CAUTION: If this disk is part of a non-redundant disk, back up your data

 

immediately. If the disk fails, you cannot recover the data.

Related Alert

Clear Alert Number: None

Information

Related Alert Number: None

 

 

Local Response Agent (LRA) Number: 2070

SNMP Trap

903

Numbers

 

Event ID — 2095

Description

SCSI sense data %1.

71

Page 71
Image 71
Dell 7.4 manual Physical disk rebuild completed