Extron electronic DVS 605 manual Commands and Responses, Password Information, Error Responses

Models: DVS 605

1 98
Download 98 pages 46.7 Kb
Page 41
Image 41
Password Information

Password Information

The ] Password: prompt requires a password (administrator level or user level) followed by a carriage return. The prompt is repeated if the correct password is not entered.

If the correct password is entered, the unit responds with ] Login Administrator ] or ] Login User ], depending on password entered. If passwords are the same for both administrator and user, the unit defaults to administrator privileges.

Error Responses

When the DVS 605 receives a valid command, it executes the command and sends a response to the host device. If the unit is unable to execute the command because the command contains invalid parameters, it returns an error response to the host.

Error Numbers

E01

— Invalid input number

E17

— Invalid command for signal type

E06

— Invalid switch attempt in this mode

E22

— Busy

E10

— Invalid command

E24

— Privilege violation

E11

— Invalid preset number

E25

— Device not present

E12

— Invalid port number

E26

— Maximum number of

 

 

 

connections exceeded

E13

— Invalid parameter

E28

— Bad filename/file not found

E14

— Not valid for this configuration

 

 

Error Response References

14= Commands that give an E14 (invalid command for this configuration) error if sent to a product whose current configuration does not support the command

24= Commands that give an E24 (privilege violation) error if not logged in at administrator level

28= Commands that may give an E28 (file not found) error

Commands and Responses

Using the Command and Response Tables

The command and response tables for SIS commands from page 42 onwards lists the commands the DVS 605 recognizes as valid. The tables show the responses that are returned to the host with a description of the command function or command execution results. Also included are examples of command in ASCII (Telnet) and URL encoded (web).

Error Responses NOTE: Upper and lower case text can be used interchangeably.

ASCII to HEX Conversion Table

Space

Figure 28. ASCII to Hexadecimal Character Conversion Table

DVS 605 • SIS Communication and Control

35

Page 41
Image 41
Extron electronic DVS 605 manual Commands and Responses, Password Information, Error Responses, Error Response References