Image Settings Page

Image Settings Page

From this page signal sampling and picture control settings can be set, user and input presets can be saved and recalled, and overscan settings can be applied.

Click on this button Figure 38. Image Settings PageSignal Sampling to open the Image Settings page.

Figure 38. Image Settings Page

Signal Sampling

In this section settings for the currently selected input signal can be adjusted. Adjustable fields are: the number of active lines, active pixels, total pixels, horizontal and vertical start settings, and the pixel phase. In addition an Auto-Image (with Fill or Follow modes) can be executed on the input.

In the Signal Sampling section, adjust an input signal setting by entering a value or clicking the up > and down < arrows in the field associated with the setting. An asterisk beside a chosen value for a signal sampling setting indicates that it is a default value for the applied input signal.

An Auto-Image can also be executed on the current input. Auto-Image automatically sizes and centers the selected input. If an unknown input is connected to the device, the processor measures and estimates the resolution of the incoming video.

To perform an Auto-Image:

1.Click on the Auto-Imagebutton. A drop-down list opens.

2.Select Auto-Image: with fill (to fill the entire video output) or

Auto‑Image: with follow (to maintain the aspect ratio of the input).

See Auto-Image in the “Input Configuration“ section on page 66 for steps to set automatic activation.

DVS 605 • Using the Default Web Pages

71

Page 77
Image 77
Extron electronic DVS 605 manual Image Settings Page, Signal Sampling