Information request

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

 

 

 

 

 

 

Information request

 

 

General information

I/i

VidX!AudX!•VtypX#StdX1)BlkX3!HrtX1#VrtX1#

 

 

PipX!]

 

Backup/restore configuration NOTE: Aud “X!” response is a “-” on the non audio model. “Vtyp” returns the detected input type (X!*\) . E1*{config type} NOTE: Blk “X3!” response is “0” unless video is muted, then the response is “1”

Query firmware

Q/q

x.xx]

View firmware version.

version

 

 

 

Query full firmware

*Q/*q

x.xx.xxxx]

View full firmware version details.

version

 

 

 

Query part number

N/n

zz-zzz-zz]

View part number.

View internal

E20STAT}

Stat20X1!]

Temperature in degrees Celsius.

temperature

 

 

 

Backup/restore configuration

Cfg1*{config NOTE: {config type} = 0 = IP config (ip.cfg), 1 = event config (event.cfg), 2 = unit specific parameters (box.cfg), type}] The files are stored on directory /nortxe-backup created on the unit by the “save” commands.

Save device

E1*{config type}

Cfg1*{config

Save unit configuration to file system.

configuration

XF}

type}]

 

Restore device

E0*{config type}

Cfg1*{config

Restore unit configuration from file system.

configuration

XF}

type}]

 

 

 

 

 

Product naming

 

 

 

E0*{config type} NOTE: The 24 superscript shown below indicates that the user will get an E24 error on an IP Link-based device Product naming (such as the DVS 605) if the user is not logged in as Administrator when trying to alter names.

Set unit name 24

EX1@CN}

IpnX1@]

Set unit name to X1@.

Set unit name to

E•CN}

IpnX10)]

Set unit name to default X10).

factory default 24

 

 

 

View unit name

ECN}

X1@]

View unit name.

EX1@CN} NOTE: X! = Input selection, 1 to 5

X# = Input video format, 0 = No signal detected (only valid for detected input format query, such as X!*\), 1 = RGB,

2 = YUV Auto, 3 = RGBcvS, 4 = S-video, 5 = Composite, 6 = DVI/HDMI (Only available for IN3, IN4, and IN5)

X1) = Input standard, 0 = No signal detected (current input), 1 = NTSC 3.85, 2 = PAL, 3 = NTSC 4.43, 4 = SECAM

- = N/A (occurs when input is an active RBG, YUV Auto [but not NTSC/PAL], or HDMI signal

X1! = Internal temperature (in degrees Celsius)

X1@ = Unit name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and the minus sign/hyphen (-).

The first character must be an alpha character. The last character must not be a minus. No blank or space characters are

permitted, and no distinction is made between upper- and lowercase.

X1# = Horizontal and vertical frequencies (format is three digit with single decimal and leading zeros for example, 075.3)

X3! = Video mute: 0 = off/disable, 1 = on/enable (mute to black)

X10) = Default name: combination of model name and last 3 pairs of MAC address (for example DVS-605-Series-07-8C-EC)

DVS 605 • SIS Communication and Control