Extron electronic DVS 605 manual Reset Device Page, device name, DHCP setting, and port mapping

Models: DVS 605

1 98
Download 98 pages 46.7 Kb
Page 95
Image 95
Reset Device Page

Reset Device Page

This page allows the user to reset the device.

Click on this button Figure 53. Reset Device Page to open the page.

Figure 53. Reset Device Page

There are three reset options available:

Reset scaler settings to default (Retains IP)

Reset scaler settings, and delete user files (Retains IP)

Reset scaler settings, delete user files, and reset IP settings Depending on the selected reset option, different settings are cleared.

Reset scaler settings to default (Retains IP) — Resets the settings associated with input settings, the output image, EDID, PIP, and audio, and also includes presets and auto memories, except Ethernet settings.

NOTE: Ethernet settings include the IP address, subnet mask, gateway IP address,

device name, DHCP setting, and port mapping.

Reset scaler settings, and delete user files (Retains IP) — Resets all settings on the device to factory defaults (deletes user files), except the Ethernet settings.

Reset scaler settings, delete user files, and reset IP settings — Resets all settings on the device to factory defaults (deletes user files) including the Ethernet settings.

Ethernet settings will default to DHCP set to Off, IP address = 192.168.254.254.

To reset the device:

1.Click the radio button of the desired reset option.

2.Click Reset. A confirmation dialog box opens.

3.In the dialog box, click Yes to continue with the reset, or No to abort the reset.

DVS 605 • Using the Default Web Pages

89

Page 95
Image 95
Extron electronic DVS 605 manual Reset Device Page, device name, DHCP setting, and port mapping