Extron electronic DVS 605 Presets User presets, User preset name, Input presets, PIP presets

Models: DVS 605

1 98
Download 98 pages 46.7 Kb
Page 56
Image 56
Presets

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

Presets

User presets

Recall preset

1*X2#.

1RprX2#]

Save preset

1*X2#,

1SprX2#]

Delete/clear preset

EX1*X2#PRST}

PrstX1*X2#]

Recall user preset X2# for selected input. Save user preset X2# for selected input.

Clears user preset X2#, and sets user preset X2# name to [unassigned].

User preset name

Write name

E1*X2#,X1$PNAM}

Pnam1*X2#,X1$]

Set the user preset X2# name to X1$.

Read name

E1*X2#PNAM}

X1$]

Read the name for user preset X2#.

User preset name NOTE: To restore a default user preset name, enter a single space character for X1$; unassigned presets = “[unassigned]”. Valid only Input presets for previously saved presets.

Input presets

Recall preset

2*X2$.

2RprX2$]

Save preset

2*X2$,

2SprX2$]

Delete/clear preset

EX2*X2$PRST}

PrstX2*X2$]

Recall input preset X2$ for selected input. Save input preset X2$ for selected input.

Clears input preset X2$, and sets input preset X2$ name to [unassigned].

Input preset name

Write name

E2*X2$,X1$PNAM}

Pnam2*X2$,X1$]

Set the input preset X2$ to X1$.

Read name

E2*X2$PNAM}

X1$]

Read the name for input preset X2$.

Input preset name NOTE: To restore a default input preset name, enter a single space character for X1$; unassigned presets = “[unassigned]”.

PIP presets

Recall preset

3*X2#.

3RprX2#]

Recall PIP preset X2# without inputs.

without input

 

 

 

Recall preset

4*X2#.

4RprX2#]

with input

 

 

Save preset

4*X2#,

4SprX2#]

Delete/clear preset

EX4*X2#PRST}

PrstX4*X2#]

Recall PIP preset X2# with inputs.

Save PIP layout and inputs to preset X2#.

Resets the PIP preset X2#, and PIP preset X2# name back to default factory settings.

PIP preset name

Write name

E3*X2#,X1$PNAM}

Pnam3*X2#,X1$]

Set the PIP preset X2# to X1$.

Read name

E3*X2#PNAM}

X1$]

Read the name for PIP preset X2#.

PIP presets NOTE: To restore a default PIP preset name, enter a single space character for X1$; default = “PIP preset XX” where “XX” is the current

preset number (for example 05).

NOTE: X1$ = Text label/preset name: up to 16 characters

X2# = User presets or PIP presets: 1 to 16

X2$ = Input presets: 1 to 128

User Presets

Input Presets

PIP Presets

Color

H/V Window

Input Type

Color

H Start

H/V Window

Main H/V

PIP H/V

 

Position

 

 

 

Position

Window Position

Window Position

 

 

 

 

 

 

 

 

Tint

H/V Window

Preset Name

Tint

V Start

H/V Window

Main H/V

PIP H/V

 

Size

 

 

 

Size

Window Size

Window Size

 

 

 

 

 

 

 

 

Contrast

H/V Image

Audio Gain/

Contrast

H Active

H/V Image

Main H/V

PIP H/V

 

Position

Attenuation

 

 

Position

Image Position

Image Position

 

 

 

 

 

 

 

 

Brightness

H/V Image

 

Brightness

V Active

H/V Image

Main H/V

PIP H/V

 

Size

 

 

 

Size

Image Size

Image Size

 

 

 

 

 

 

 

 

Detail

 

 

Detail

Phase

 

Main Input #

 

 

 

 

 

 

 

 

 

Preset Name

 

 

Film Mode

Total Pixels

 

PIP Input #

 

 

 

 

 

 

 

 

 

DVS 605 • SIS Communication and Control

50

Page 56
Image 56
Extron electronic DVS 605 Presets User presets, User preset name, Input presets, Input preset name, PIP presets, Command