Hardwired IR port

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

 

 

 

 

 

 

 

 

Hardwired IR port

 

 

 

Enable IR port

65*0#

IRDisable0]

Enables the hard wired port and allows IR

(allows IR)

 

 

control input.

Disable IR port

65*1#

IRDisable1]

Disables the hard wired port (default).

(blocks IR)

 

 

 

View IR setting

65#

X(]

View the current IR Disable setting.

Picture In Picture

Picture In Picture NOTE: HDMI input 5 cannot be used for PIP.

PIP on/off

PIP on

EX2&PIP}

PipX2&]

Turn on PIP and display input X2&. X2& is a

 

 

 

two digit response (for example, 01).

PIP off

E0PIP}

Pip00]

Turn PIP off.

View PIP selection

EPIP}

X2&]

View PIP selection (X2& is a two digit

 

 

 

response, for example, 01).

 

 

 

Swap main/PIP windows

 

 

Swap

%

Tke]

Swap between main and PIP window.

On-Screen Menu time-out

PIP on/off NOTE: Setting the time-out to 501 disables the OSD time-out (never times out). Setting the time-out to 0 disables the OSD.

Set menu time-out

EX2%MDUR}

MdurX2%]

Set the OSD to X2% seconds.

View time-out

EMDUR}

X2%]

View time-out settings.

Reset commands

Erase user web

E<filename>EF}

Del<filename>]

Erase named files.

pages and files 24 28

 

 

 

Erase current

E/EF}

Ddl]

Erase current directory and its files.

directory and

 

 

 

files 24 28

 

 

 

Erase current

E//EF}

Ddl]

Erase current directory and its

directory and

 

 

subdirectories.

subdirectories 24 28

 

 

 

Erase flash

EZFFF}

Zpf]

Erase the flash memory.

memory 24

 

 

 

Reset all device

EZXXX}

Zpx]

Retains Ethernet settings

settings to factory

 

 

 

default settings 24

 

 

 

Absolute system

EZQQQ}

Zpq]

Includes resetting networking to DHCP =

reset 24

 

 

Off, IP = 192.168.254.254 (default address)

Absolute system

EZY}

Zpy]

 

reset (but retain IP) 24

 

 

 

Swap main/PIP windows NOTE: This reset EZY is similar to ZQQQ but excludes IP address, subnet mask, gateway addresses, unit name,

DHCP setting, and port mapping (Telnet/web/direct access) in order to maintain communications with device. Recommended after a firmware update.

On-Screen Menu time-out NOTE: X( = Enable/disable: 0 = off/disable, 1 = on/enable

X2% = On-screen menu time-out: (default = 3 seconds)/output sync time-out (default = 501 - never)

0 = OSD never displayed/output sync is instantly disabled with no active input,

1 to 500 in 1 second increments, 501 = OSD never times out/output sync never times out

X2& = PIP window input selection: 0 to 4 (0 = off)

DVS 605 • SIS Communication and Control

54

Page 60
Image 60
Extron electronic DVS 605 Hardwired IR port, Picture In Picture, PIP on/off, Swap main/PIP windows, On-ScreenMenu time-out