Additional Description

Command

ASCII Command

Response

Additional Description

 

(host to scaler)

(scaler to host)

 

Input name

 

 

 

Write input name

EX!,X1$NI}

NmiX!,X1$]

Set the name X1$ for input X!.

Read input name

EX!NI}

X1$]

View input X! name X1$.

NOTE: To clear an input name, a single space character should be entered for X1$. This resets the input name to the

default value.

 

 

Auto-Image

 

 

 

Enable

X!*1A

ImgX!*1]

Activate Auto-Image for input X!.

Disable

X!*0A

ImgX!*0]

Turn Auto-Image off for input X!.

View status

X!A

X(]

View Auto-Image setting: (0 = on,

 

 

 

1 = off).

Execute

0*A

Img0]

Execute an Auto-Image to the selected

 

 

 

input (follows current aspect setting).

Execute and Fill

1*A

Img1]

Execute an Auto-Image and fill entire

 

 

 

output.

Execute and Follow

2*A

Img2]

Execute an Auto-Image and follow the

 

 

 

aspect ratio of the input.

Auto-Image threshold value (minimum luminosity value which the scaler defines

as active video for Auto-Image)

Set value

EX3@ALVL}

AlvlX3@]

Set global Auto-Image luminosity value

 

 

 

X3@.

View

EALVL}

X3@]

View global Auto-Image luminosity value

 

 

 

X3@.

Horizontal start

 

 

 

Specify a value

EX!*X$HSRT}

HsrtX!*X$]

Set horizontal location of first active pixel

 

 

 

for input X!.

Increment value

EX!+HSRT}

HsrtX!*X$]

Increment horizontal start position.

Decrement value

EX!-HSRT}

HsrtX!*X$]

Decrement horizontal start position.

View

EX!HSRT}

X$]

Show horizontal location of first active

 

 

 

pixel for input X!.

Vertical start

 

 

 

Specify a value

EX!*X$VSRT}

VsrtX!*X$]

Set vertical location of first active pixel for

 

 

 

input X!.

Increment value

EX!+VSRT}

VsrtX!*X$]

Increase vertical start.

Decrement value

EX!-VSRT}

VsrtX!*X$]

Decrease vertical start.

View

EX!VSRT}

X$]

Show vertical location of first active pixel

 

 

 

for input X!.

NOTE: X! = Input selection: 1 to 5

X$ = Horizontal/vertical start: 0 to 255 (default midpoint = 128)

X( = Enable/disable: 0 = off/disable, 1 = on/enable

X1$ = Text label/preset name, up to 16 characters

X3@ = Auto-Image threshold value: 0 (black) though 100 (white), default = 25