List of the command abbreviations

Interfaces

List of the command abbreviations

General commands

TTY

 

Switch over from the ANSI terminal (menu-orientated operation according to the SAA standard)

 

 

into the TTY terminal mode (line-oriented operation).

ANS

 

Switch over from the TTY terminal mode (line-orientated operation) to the NASI terminal mode (menu-

 

 

orientated operation according to SAA standard.

?

 

Request a list of the command abbreviations (functions only in TTY mode).

VER

 

Request a list of version numbers for the signal hardware and software components of the MSK 33.

PAS

 

The locked-in password can be newly assigned.

 

 

(max. 16 characters).

 

LAN

 

The language of the help guide via modem can be switched between German and English.

Switch-over of the operating type of the MSK 33

SAT

 

Switch over the MSK 33 into operating type satellite reception.

TV-

 

Switch over the MSK 33 into operating type cable reception.

FM-

 

Switch over the MSK 33 into the operating type FM reception.

Measurements with the MSK 33

 

RF-

 

The level of the carrier of the receiving signal is measured.

BIA

 

The current supply form the antenna socket for the satellite LNB or the cable head amplifier is measured.

Changing

settings of the MSK 33

 

FRE

 

Enter-in the frequency of the desired transmitter

 

 

Entry:

Action:

 

 

FRE <RET>

You are asked for the frequency.

 

 

FRE 266 <RET>

266 MHz are set as default.

 

 

FRE 10.7 G <RET>

10700 MHz are set as default.

 

 

Note: The comma position

must be entered in as a point.

CHA

 

Enter in the channel of the desired transmitter (only in TV mode).

 

 

Entry:

Action

CHA<RET>

 

 

You are asked for the channel.

 

 

CHA 14 <RET>

14 is set.

 

 

CHA s 16 <RET>

Special channel 16 is set.

LO-

 

Set LNB oscillator of the

satellite system (only in Sat-mode).

 

 

Entry:

Action:

 

 

LO-<RET>

You are asked for the frequency.

 

 

LO-9750 <RET>

9750 MHz are set as default.

 

 

LO-10.7 G <RET>

10700 MHz are set.

 

 

Note: The comma position

must be enter-in with a point. If LO-0 is entered, the entered frequency is

 

 

interpreted as 1.IF.

 

22 k

 

The 22KHz switching signal on the antenna connection is activated or deactivated.

SUP

 

Activated supply voltage for LNB or cable head station and set or deactivate to a voltage.

 

 

Entry:

Action:

 

 

SUP <RET>

You are asked for the voltage.

 

 

SUP 14.5 <RET>

14.5 volts are set. The unit, volt, does not have to be given.

 

 

SUP 0 V

The supply voltage is deactivated.

 

 

Note: The set voltage is

separately administered for the single operating types of the MSK 33.

Producing

digital control

 

DIS

 

the DiSEqC control signal is edited and transmitted.

 

 

Entry:

Action:

 

 

DIS <RET>

You are asked for the Hex-byte(s) which are to be sent.

 

 

DIS E0 12 01 12

The combination FRAME-Byte, ADDRESS-Byte, COMMAND-Byte + max. 3

 

 

34 <RET>

DATEN-Bytes are transmitted.

VSE

 

The VSEQ control signal is

edited and transmitted. VSEQ

 

 

Entry:

Action:

 

 

VSE <RET>

You are asked for hex-byte which is to be sent.

 

 

VSE E0 <RE>

The entered-in byte is transmitted.

94

Page 94
Image 94
DreamGEAR MSK 33 List of the command abbreviations, Interfaces, General commands, Measurements with the MSK, Changing