Digital Measurements

Level measurement DIGITAL (Min./Max. levels)

Calls up the level measurement DIGITAL as well as MIN./MAX. In this function, minimal and maximal levels are measured. This function serves for monitoring the measurement points to level fluctuations. Even after exiting the menu, the MSK 33 stays set to DIGITAL reception.

When the button, „measure,“ is pressed, this display (example) appears on the screen:

Display of the minimal level 78.0 dBµV and the maximal level 82.5 dBµV.

Display of the Sat frequency, the level and note to digital reception „D“.

As long as this measurement function is called up, the MSK 33 measures the minimal and maximal levels. This measurement function serves for monitoring the check points for level fluctuations.

A „D“ in front of the level display means, that the MSK 33 has been set to digital reception. Even after exiting the menu, the MSK 33 stays set to DIGI- TAL reception.

The MSK 33 can be switched to the ANALOG menu for ANALOGUE reception (refer to the respective section).

42

Page 42
Image 42
DreamGEAR MSK 33 manual Level measurement Digital Min./Max. levels