DreamGEAR MSK 33 TV control menu, TV-DiSEqC /VSEC menu, LNB U= 0.0 V I= 0 mA, LNB supply voltage

Models: MSK 33

1 114
Download 114 pages 49.3 Kb
Page 44
Image 44
TV control menu
BACK
22 kHz off>
DiSEqC
VSEC

TV Operation

TV control menu

22 kHz control signal

LNB: U= 0.0 V I= 0 mA

The field lights up yellow, as soon as the softkey is pressed. The switchable 22 kHz signal over

superimposes the supply voltage. By pressing the button once more, the 22 kHz signal is disconnected

LNB supply voltage

(Remote power supply)

The field lights up yellow, as soon as the softkey is pressed. The supply voltage for the vertical polarisation 14.0 V is

now switched on. For control, the LED above the RF input socket lights up. The

voltage value can be entered in with the buttons, 0...9, or changed in the range from 10 V to 20 V with the cursor buttons, ◄►. By pressing the button once more, the LNB supply voltage is disconnected again.

Remote supply voltage

See above.

The remote supply voltage is

-disconnectable= 0V

-changeable from 10…20 V in 0.1 V increments

-short-circuit proof max. current 500 mA

LNB: U = 14,6V I = 181mA

This field displays the current drain (I = 181 mA) and the supply voltage (14.6 V) of the LNB.

Checking the supply voltage in a remotely fed system

Switch the remote power feeding voltage of the MSK 33 to „OFF.“ Connect the sys- tem with the MSK 33 (RF input socket with antenna socket). You can now read on the screen the output voltage of the remotely fed-in unit in the checked system

Calling up the menu DiSEqC / VSEC

DiSEqC

VSEC

In this menu, all DiSEqC control possibilities can be set (refer to the respective sec- tion).

TV-DiSEqC /VSEC menu

The menu explanations are found in the respective section.

44

Page 44
Image 44
DreamGEAR MSK 33 TV control menu, TV-DiSEqC /VSEC menu, LNB U= 0.0 V I= 0 mA, LNB supply voltage, Remote supply voltage